Data centers consume roughly 1% of the total electricity demand, while ICT as a whole consumes around 10%. Demand is growing exponentially and, left unchecked, will grow to an estimated increase of 20% or more by 2030. This book covers the energy consumption and minimization of the different data center components when running real workloads, taking into account the types of instructions executed by the servers. It presents the different air- and liquid-cooled technologies for servers and data centers with some real examples, including waste heat reuse through adsorption chillers, as well as the hardware and software used to measure, model and control energy. It computes and compares the Power Usage Effectiveness and the Total Cost of Ownership of new and existing data centers with different cooling designs, including free cooling and waste heat reuse leading to the Energy Reuse Effectiveness. The book concludes by demonstrating how a well-designed data center reusing waste heat to produce chilled water can reduce energy consumption by roughly 50%, and how renewable energy can be used to create net-zero energy data centers.
Auteur
Luigi Brochard was a Distinguished Engineer at IBM, then at Lenovo Data Center Group where he designed energy aware software systems. He is now a consultant on energy efficiency.
Vinod Kamath worked with IBMx86 as a thermal engineer and is now a Senior Technical Staff Member with the Lenovo Data Center Group, where he is responsible for the water-cooled server design.
Julita Corbalán is Associate Professor at the UPB, associate researcher at BSC-CNS and technical leader for the EAR Lenovo-BSC project.
Scott Holland is a thermal engineer with Lenovo Data Center Group and is responsible for providing direct liquid-cooling solutions. His most recent project was the Lenovo ThinkSystem SD650.
Walter Mittelbach has been working on adsorption chillers at Fraunhofer ISE since 1995. He also founded two companies: Fahrenheit GmbH (2002) and Sorption Technologies GmbH (2018).
Michael Ott is a senior researcher in the HPC division at Leibniz Supercomputing Centre, where he leads the research activities on energy efficiency.
Contenu
Introduction ix
Chapter 1. Systems in Data Centers 1
1.1. Servers 1
1.2. Storage arrays 3
1.3. Data center networking 4
1.4. Components 5
1.4.1. Central processing unit 5
1.4.2. Graphics processing unit 7
1.4.3. Volatile memory 8
1.4.4. Non-volatile memory 10
1.4.5. Non-volatile storage 10
1.4.6. Spinning disks and tape storage 13
1.4.7. Motherboard 15
1.4.8. PCIe I/O cards 16
1.4.9. Power supplies 17
1.4.10. Fans 18
Chapter 2. Cooling Servers 19
2.1. Evolution of cooling for mainframe, midrange and distributed computers from the 1960s to 1990s 19
2.2. Emergence of cooling for scale out computers from 1990s to 2010s 20
2.3. Chassis and rack cooling methods 23
2.4. Metrics considered for cooling 27
2.4.1. Efficiency 27
2.4.2. Reliability cost 28
2.4.3. Thermal performance 29
2.5. Material used for cooling 31
2.6. System layout and cooling air flow optimization 32
Chapter 3. Cooling the Data Center 37
3.1. System cooling technologies used 37
3.2. Air-cooled data center 38
3.2.1. Conventional air-cooled data center 38
3.3. ASHRAE data center cooling standards 40
3.3.1. Operation and temperature classes 40
3.3.2. Liquid cooling classes 41
3.3.3. Server and rack power trend 42
3.4. Liquid-cooled racks 43
3.5. Liquid-cooled servers 46
3.5.1. Water heat capacity 46
3.5.2. Thermal conduction module 47
3.5.3. Full node heat removal with cold plates 48
3.5.4. Modular heat removal with cold plates 50
3.5.5. Immersion cooling 50
3.5.6. Recent DWC servers 51
3.6. Free cooling 54
3.7. Waste heat reuse 54
3.7.1. Reusing heat as heat 54
3.7.2. Transforming heat with adsorption chillers 55
Chapter 4. Power Consumption of Servers and Workloads 65
4.1. Trends in power consumption for processors 65
4.1.1. Moore's and Dennard's laws 68
4.1.2. Floating point instructions on Xeon processors 72
4.1.3. CPU frequency of instructions on Intel Xeon processors 73
4.2. Trends in power consumption for GPUs 74
4.2.1. Moore's and Dennard's laws 77
4.3. ACPI states 78
4.4. The power equation 83
Chapter 5. Power and Performance of Workloads 87
5.1. Power and performance of workloads 87
5.1.1. SKU power and performance variations 87
5.1.2. System parameters 89
5.1.3. Workloads used 92
5.1.4. CPU-bound and memory-bound workloads 92
5.1.5. DC node power versus components power 93
5.2. Power, thermal and performance on air-cooled servers with Intel Xeon 94
5.2.1. Frequency, power and performance of simple SIMD instructions 95
5.2.2. Power, thermal and performance behavior of HPL 98
5.2.3. Power, thermal and performance behavior of STREAM 103
5.2.4. Power, thermal and performance behavior of real workloads 107
5.2.5. Power, thermal and frequency differences between CPUs 115
5.3. Power, thermal and performance on water-cooled servers with Intel Xeon 124
5.3.1. Impact on CPU temperature 124
5.3.2. Impact on voltage and frequency 125
5.3.3. Impact on power consumption and performance 127
5.4. Conclusions on the impact of cooling on power and performance 131
Chapter 6. Monitoring and Controlling Power and Performance of Servers and Data Centers 133
6.1. Monitoring power and performance of servers 133
6.1.1. Sensors and APIs for power and thermal monitoring on servers 134
6.1.2. Monitoring performance on servers 140
6.2. Modeling power and performance of servers 142 <p...